dragon

( Vol 45 , Issue 08 ) | 20 Nov 2025

Day

Hour

Min

Sec

( Vol 45 , Issue 08 ) | 30 Nov 2025

Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering

Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering (ISSN:0258-8013) is a monthly peer-reviewed scopus-indexed journal from 1985 to present. The publisher of this journal is Chinese Society for Electrical Engineering. PCSEE committed to gathering and disseminating excellent research achievements. The journal welcomes all kind of research/review/abstract papers regarding Engineering: Electrical and Electronic Engineering.

Scopus Index (2025)
AIM AND SCOPES

Zhongguo Dianji Gongcheng Xuebao/Proceedings Of The Chinese Society Of Electrical Engineering

  • Electrical Engineering

  • Biological Biosystem Engineering

  • Hardware-software co-design and interfacing

  • Nanotechnology

  • Turbines micro-turbines

  • Power quality

  • Energy optimization

  • HVDC transmission

  • Telecommunication Engineering

  • Integrated Engineering

  • Semiconductor chip

  • Advanced control theories and applications

  • FACTS devices

  • High voltage engineering

  • Electric drives

  • Power electronics

  • Electro-mechanical System Engineering

  • Electronic Engineering

  • Peripheral equipments

  • Machine design and optimization

  • Insulation systems

  • Electrical machines

  • Semiconductor chip

  • Electronic Engineering

All Journal Published Here

Zhongguo Dianji Gongcheng Xuebao/Proceedings Of The Chinese Society Of Electrical Engineering

Response-driven Adaptive Load Shedding Strategy Facing to Refined Frequency Recovery Criterion Requirement of Receiving-end Power System

With the large number of frequency-sensitive equipment in the power grid, code of power system security proposes more detailed and strict frequency recovery criterion (FRC) to make the frequency-sensitive equipment safely ride through frequency dynamics, and ensure frequency stability. To face to the FRC requirement, this paper proposes a response-driven adaptive load shedding strategy for the receiving-end power system. An FRC-oriented intelligent fuzzy controller of load shedding is developed, and logical inference rules for preventing over- or under-shedding problems are introduced. Base

Zoned Oscillation Suppression Method for High-frequency Oscillation in Doubly Fed Wind Farms

After high-frequency oscillation occurs in a certain area of the wind farm, it may affect other areas, leading to large-scale oscillation of the entire wind farm. Taking a domestic doubly-fed wind farm with static var generator (SVG) as an example, the equivalent high frequency impedance model of the wind farm is established. Then, the phenomenon of large-scale oscillation in wind farms caused by high-frequency oscillation in a certain area is studied. The results show that wind farms can be divided into regions by contacting transformers, and the high-frequency oscillation risk of wind far

Analytical Calculation Method of Outer Loop Controller Parameters of HVDC Converter Station Connected to Weak AC Grid and Analysis of Limiting Factors

The dynamic response speed of AC voltage of flexible high voltage direct current (HVDC) converter connected to weak AC grid is manly related to the parameters of AC voltage controller, SCR, steady state operating points and equivalent capacitance paralleled at point of common coupling (PCC). Firstly, due to the lack of analytical calculation of the parameters of AC voltage controller and analysis of their limiting factors, the key influence variables and participations of eigenvalues related to dynamic response and stability have been analyzed according to the distribution of zeros and pole

A Fault Toleration Strategy for DC Voltage Sensors in Cascaded Photovoltaic Systems Based on Active-coupling Power Units

Cascaded H-bridge (CHB) is a promising topology for utility-scale photovoltaic generation due to its advantages like modularity, scalability, and capability of direct access to medium voltage grids. However, owing to the large quantity of components in the circuit, CHB is less reliable. As one common fault, the DC-link voltage sensor fault will cause the current/voltage mistracking and power mismatch, which will further lead to unbalanced DC-link voltages and even system instability. To address this issue, in this paper, a coupling-dc strategy is proposed to improve the system reliability f

Research on Protection Scheme of Regenerative Braking Energy Utilization System of Electrified Railway

Regenerative braking energy utilization system plays an important role in the recovery and utilization of renewable energy, energy saving and carbon reduction of electrified railway. However, the regenerative braking energy utilization system based on power flow control technology will change the original power flow of traction power supply system, and its fault protection is very important to ensure the safety of electrified railway operation. Therefore, this paper studies the fault protection scheme of regenerative braking utilization system of electrified railway. Firstly, according to t